Orlando |
Code of Ordinances |
Chapter 58. ZONING DISTRICTS AND USES |
Part 5. ACCESSORY USES AND STRUCTURES |
Appendix 5B. SPECIFIC ACCESSORY USES AND STRUCTURES |
Appendix 5. REFUSE AND RECYCLING DISPOSAL CONTAINERS |
§ 58.954. Roll-Off Compactor Container Location Requirements.
No roll-off compactor container pad(s) shall be located within any required front or street side yard setback. No such container shall be located in any required parking space or vehicular use area, or in any required bufferyard or landscaping area.
Container Pads. Roll-off compactor container pad(s) shall be provided for all roll-off compactor containers, and shall be constructed of minimum 3000 P.S.I. concrete, steel reinforced, 6 inches thick, and shall comply with the following minimal dimension requirements.
Service Access. A paved service vehicle access apron, constructed to a minimum 60,000 lb. /capacity requirement and extending a minimum of 45 feet in front of each roll-off compactor container is required. Service height clearance of 25 feet is required in the container service access area.
Electrical Requirements. The industry recommendations for roll-off compactor electrical requirements are: 3 phase, 460/-480 volt, 60 amp. electrical service to each compactor location. Other electrical requirements may be approved and certified serviceable by an authorized City Franchisee for certain specialized compaction equipment.
Roll-Off Compactor Container Requirements; Exception. Exceptions to the dimensional pad and service access requirements of this section may be approved by the Refuse Collection Bureau when each such exception has been certified serviceable by an authorized City Franchisee.
(Ord. of 9-16-1991, Doc. #25094; Ord. of 5-20-1996, Doc. #29361; Ord. of 1-24-2005, § 18, Doc. #050124909; Ord. No. 2019-8 , § 1, 3-11-2019, Doc. #1903111201)